Sargent AD8674 ETL Concealed Vertical Rod Exit Device for Aluminum Doors – Fail Secure Electrified Lever Trim, Non-Rated, Grade 1
The Sargent AD8674 ETL is a Grade 1 wide-stile concealed vertical rod (CVR) exit device for aluminum doors with fail secure outside trim. Electrified fail-secure ET trim. Power off locks the outside lever. No outside cylinder. Specify 12 VDC or 24 VDC. The AD8600 is a panic device only. Sargent does not offer fire exit hardware on aluminum doors.
Institutional Grade Features & Benefits
- Function 74: Electrified fail secure: power off locks the lever. No cylinder. 12 VDC or 24 VDC. Inside push rail is always free for egress.
- Concealed top and bottom rods inside the aluminum door for a clean look and tamper resistance. Order LHR or RHR.
- L lever on ET escutcheon trim (774-4). This function has no outside cylinder.
- ANSI/BHMA A156.3 Grade 1. UL305 panic. Hex key dogging is standard.
- Rail lengths E, F, J and G for 24 to 32, 33 to 36, 37 to 42 and 43 to 48 inch doors.
- Strikes: 640 strike kit, top and bottom (aluminum door). Door thickness 1-3/4 inch minimum; 31- for over 1-3/4 to 2-1/4 inch. 4-1/2 inch minimum stile.
- Device centerline 41 inches above finished floor (38 inches for elementary schools).
- Electric options on this family include 53- latchbolt monitor, 55- rail signal switch, 56- motorized latch retraction and 59- delayed egress.
- Choose 12 VDC or 24 VDC for the electrified ET trim.
- Non-keyed listing. No LA / LC / 60 / 70 cylinder options.
- Finishes on this listing: US32D Satin Stainless Steel / BHMA 630; US3 Polished Brass; US4 Satin Brass; US10 Satin Bronze; US10B Oil Rubbed Bronze; US10BE Oil Rubbed Bronze Equivalent.
Outside Trim Function: Fail Secure Electrified (Function 74)
The ETL outside lever on this AD8674 uses the fail secure function:
- Power Off: Locks the outside lever (fail secure).
- Cylinder: None. This is a non-keyed listing.
- Voltage: Choose 12 VDC or 24 VDC.
- Free Egress Always: Pushing the inside rail always retracts the latches.
- Lever: L design on this listing.
Technical Details
| Feature | Details |
|---|---|
| Device | AD8674 ETL wide-stile concealed vertical rod exit device |
| Door type | Aluminum Doors |
| Function | 74 Electrified fail secure: power off locks the lever. No cylinder. 12 VDC or 24 VDC. |
| Trim | ETL (774-4 ET control) with L lever |
| Fire class | Non-rated |
| Grade | ANSI/BHMA A156.3 Grade 1 |
| Listing | UL305 panic |
| Handing | LHR or RHR |
| Rail | E 24-32 in, F 33-36 in, J 37-42 in, G 43-48 in door |
| Strikes | 640 strike kit, top and bottom (aluminum door) |
| Door height | Required on the order. 120 in max door opening |
| Door thickness | 1-3/4 in minimum; 31- for over 1-3/4 to 2-1/4 in |
| Stile | 4-1/2 in minimum |
| Centerline | 41 in AFF standard; 38 in for elementary schools |
| Fasteners | Machine screws supplied |
| Keying | None -- non-keyed trim |
| Finish | US32D Satin Stainless Steel / BHMA 630; US3 Polished Brass; US4 Satin Brass; US10 Satin Bronze; US10B Oil Rubbed Bronze; US10BE Oil Rubbed Bronze Equivalent |
| Voltage | 12 VDC or 24 VDC (choose one) |
| General - US Finishes | US32D - Satin Stainless Steel/ 630 or US3 - Polished Brass or US4 - Satin Brass or US10 - Satin Bronze or US10B - Oil Rubbed Bronze or US10BE - Oil Rub Bronze Equal |
| Voltage | 12 VDC or 24 VDC |
| Sargent Exit Device Rail Length | F - 36" Wide Door or J - 42" Wide Door or G - 48" Wide Door or E - 24" Wide Door |
| Door Handing | RHR or LHR |
| Sargent Exit Device Prefixes | 43 - Flush End Cap or 53 - Latchbolt Monitor Switch – available with 55, 56, 58, AL options) or 54 - Outside Lever Monitoring (not available with 04/10 function) or 55 - Signal Switch in Rail or 56 - Motorized Electric Latch Retraction (Minimum door width for narrow & wide stile is 28") or 58 - Electric Dogging or 59 - Electroguard Delay Egress (Not available with 16-, 53-, 55-, 56-, 58- Options) |
| Brand | Sargent |
| Series | Sargent - 80 Series, Sargent - 700 ET Series |
| Exit Device Type | CVR Exit Device |
| Exit Device Fire Rating | Non Rated Door |
| Exit Device Trim Function | Fail Secure |
| Door Height | 7'0" Dr Ht |
| Door Opening Width | 24 Inches, 36 Inches, 42 Inches, 48 Inches |
Sargent 80 Series Catalog
View
Sargent 80 Series Parts Manual
View
Sargent 8600 Series Installation Instructions
View
Sargent AD8600 Wide Stile CVR Aluminum Door Template
View
Sargent 700 Series ETL Trim
View
Sargent 700 Trim Instructions
View
Sargent 700-4 ET Control Trim Template (MD8600)
View
Sargent 54-700-4 and 773-4 / 774-4 Electrified ET Trim Template (MD8600 / WD8600)
View
Sargent 80 Series Electromechanical Options Template
View
43 Prefix Instructions
View
53 Prefix Instructions
View
59 Prefix Instructions
View
Recently Viewed Items
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.