Sargent 12-8510 ETL Narrow Stile Rim Exit Device – Dummy Lever Trim (Pull Only), Fire-Rated, Grade 1
The Sargent 12-8510 ETL is a Grade 1 narrow stile rim exit device with dummy ET lever trim (710). Dummy trim: no outside operation. The ET control is used as a pull only. This listing is the 12- fire-labeled device: UL10C fire exit hardware for single metal doors up to 4 ft x 8 ft, 3 hour. The non-rated sibling is a separate listing.
Institutional Grade Features & Benefits
- Function 10: Dummy trim: no outside operation. The ET control is used as a pull only. Inside push rail is always free for egress.
- Narrow stile design for aluminum frame and full glass doors. Single point rim latch. Order LHR or RHR.
- L lever on ET escutcheon trim (710). This function has no outside cylinder.
- ANSI/BHMA A156.3 Grade 1. UL10C fire labeled (12- prefix). Hex key dogging is not supplied on fire-rated devices.
- Rail lengths E, F, J and G for 24 to 32, 33 to 36, 37 to 42 and 43 to 48 inch doors.
- Strike: 649 strike, supplied standard on fire-rated devices. Door thickness 1-3/4 inch minimum; order 31- for thicker doors. 2 inch minimum stile (device less trim).
- Stainless steel latch bolt with 3/4 inch throw. Device centerline 41 inches above finished floor.
- Electric options on this family include 53- latchbolt monitor, 54- outside lever monitoring, 55- rail signal switch, 56- motorized latch retraction and 59- delayed egress.
- Non-keyed listing. No LA / LC / 60 / 70 cylinder options.
- Finishes on this listing: US32D Satin Stainless Steel / BHMA 630; US3 Polished Brass; US4 Satin Brass; US10 Satin Bronze; US10B Oil Rubbed Bronze; US10BE Oil Rubbed Bronze Equivalent.
Outside Trim Function: Dummy, Pull Only (Function 10)
The ETL outside lever on this 12-8510 uses the dummy function:
- Outside Lever: Rigid pull only. It does not retract the latch.
- Cylinder: None. This is a non-keyed listing.
- Free Egress Always: Pushing the inside rail always retracts the latch.
- Lever: L design on this listing.
Technical Details
| Feature | Details |
|---|---|
| Device | 12-8510 ETL narrow stile rim exit device |
| Door type | Metal doors (fire-rated) |
| Function | 10 Dummy trim: no outside operation. The ET control is used as a pull only. |
| Trim | ETL (710 ET control) with L lever |
| Cylinder | None |
| Fire class | Fire-rated (12- prefix): single metal doors up to 4 ft x 8 ft, 3 hour |
| Grade | ANSI/BHMA A156.3 Grade 1 |
| Listing | UL10C fire exit hardware (12- prefix) |
| Handing | LHR or RHR |
| Rail | E 24-32 in, F 33-36 in, J 37-42 in, G 43-48 in door |
| Strike | 649 strike, supplied standard on fire-rated devices |
| Door thickness | 1-3/4 in minimum; 31- for thicker doors |
| Stile | 2 in minimum (device less trim) |
| Latch bolt | Stainless steel, 3/4 in throw |
| Centerline | 41 in AFF standard |
| Projection | 3 in neutral; 2-1/8 in depressed |
| Fasteners | Wood and machine screws supplied; through-bolts available |
| Keying | None -- non-keyed trim |
| Finish | US32D Satin Stainless Steel / BHMA 630; US3 Polished Brass; US4 Satin Brass; US10 Satin Bronze; US10B Oil Rubbed Bronze; US10BE Oil Rubbed Bronze Equivalent |
| General - US Finishes | US32D - Satin Stainless Steel/ 630 or US3 - Polished Brass or US4 - Satin Brass or US10 - Satin Bronze or US10B - Oil Rubbed Bronze or US10BE - Oil Rub Bronze Equal |
| Sargent Exit Device Prefixes | 43 - Flush End Cap or 53 - Latchbolt Monitor Switch – available with 55, 56, 58, AL options) or 55 - Signal Switch in Rail or 56 - Motorized Electric Latch Retraction (Minimum door width for narrow & wide stile is 28") or 59 - Electroguard Delay Egress (Not available with 16-, 53-, 55-, 56-, 58- Options) |
| Door Handing | RHR or LHR |
| Sargent Exit Device Rail Length | F - 36" Wide Door or J - 42" Wide Door or G - 48" Wide Door or E - 24" Wide Door |
| Brand | Sargent |
| Series | Sargent - 80 Series, Sargent - 700 ET Series |
| Exit Device Fire Rating | Fire Rated Door |
| Exit Device Type | Narrow Stile |
| Exit Device Trim Function | Dummy |
Sargent 80 Series Catalog
View
Sargent 80 Series Parts Manual
View
Sargent 700 ET Trim Parts List
View
Sargent 8500 Series Installation Instructions
View
Sargent 8500 Series Narrow Stile Rim Template with ET Trim
View
Sargent 700 ET Trim Installation Instructions
View
Sargent 56 Electric Latch Retraction Installation Instructions
View
Sargent 700 Series ETL Trim
View
Sargent 700-8 ETL Trim Door Prep Template
View
Sargent 80 Series Electromechanical Options Template
View
43 Prefix Instructions
View
53 Prefix Instructions
View
59 Prefix Instructions
View
Recently Viewed Items
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.