Sargent 28-2493 Fire Rated Top Latch | For 12-3727 Devices
The Sargent 28-2493 is a genuine OEM replacement Fire Rated Top Latch Assembly specifically engineered for Sargent 12-3727 Surface Vertical Rod (SVR) Exit Devices. Designed for use on UL Fire Rated doors, this assembly includes the high-strength internal latching mechanism and a protective EN (Aluminum) finish cover. This unit ensures the door remains securely deadlocked at the header during a fire event, preventing door warping and maintaining the smoke seal.
Life-Safety Grade Features & Benefits
- Direct 12-3727 Series Compatibility: Precision-calibrated to interface perfectly with the fire-rated vertical rods and lift-members of the Sargent 12-3700 series.
- Fire-Rated Integrity: Manufactured to the rigorous standards required for 12-prefix (Fire Rated) hardware, ensuring compliance with local fire and building codes.
- Architectural EN Cover Included: Comes with a factory-finished aluminum cover to shield the internal fire-rated springs and trip-levers from dust and tampering.
- Positive Deadlocking Mechanism: Features a heavy-duty internal bolt designed to provide a secure "top-point" lock that releases only when the exit device pushpad is depressed.
- OEM Precision Fit: Replacing damaged latches with the genuine 28-2493 restores the original fire listing of the opening without the need for unapproved field modifications.
Technical Specifications
- Model Number: 28-2493
- Part Type: Fire-Rated Top Latch Assembly with Cover
- Compatibility: Sargent 12-3727 Surface Vertical Rod Devices
- Finish: EN (Aluminum)
- Application: Fire-Rated Doors Only (12-Prefix Hardware)
The Sargent 28-2493 is the most critical repair part for fire-rated SVR devices. Because the top latch handles the "deadlocking" function, a worn or dirty internal trip-lever can cause the door to bounce off the strike or fail to latch entirely. On a fire-rated opening, this is a major compliance violation. Replacing the entire 28-2493 assembly ensures your fire door remains a reliable barrier during an emergency.
Installation Note: For the top latch to engage the header strike consistently, the exit device must be perfectly anchored. We highly recommend securing the 12-3727 chassis using high-strength thru bolts. A stable, thru-bolted connection prevents the device from sagging, which keeps the vertical rods in perfect alignment and prevents the 28-2493 latch from binding or "hanging up" on the strike plate.
| General - US Finishes | EN - Aluminum Enamel |
| Brand | Sargent |
| Series | Sargent - 30 Series |
| Fire Rated | Fire Rated |
| Part Type | Top Latch Assembly |
Recently Viewed Items